4 | EN Copyright © Liberty Pumps, Inc. 2023
All rights reserved. 4353000D
Check Valve
The CSP-Series kit includes a threaded check valve for use with the
discharge hose. This prevents water from draining back through
the discharge hose into the basin. When using a check valve, the
discharge line must be protected from freezing by running the
discharge deep enough below ground level to be beneath the
frost line. See Figure 1.
Power Cord
The pump power cord is equipped with a grounding conductor
and grounding-type 3-prong plug. It shall be connected to a
separately fused, grounded, 3-wire grounding-type receptacle of
15 Amp capacity with the proper 115 V. Verify all electrical wiring
and connections are in accordance with the National Electric
Code® and all applicable local codes.
Figure 1. Typical Residential Installation (recommended installation)
Operation, Maintenance and
Troubleshooting
Refer to supplied pump manual. For further questions, contact
customer service at 800-543-2550 or
support@LibertyPumps.com.
Warranty
Liberty Pumps Wholesale Products Limited
Warranty
Liberty Pumps, Inc. warrants that Liberty Pumps wholesale
products are free from all factory defects in material and
workmanship for a period of three (3) years from the date of
purchase (excluding* batteries and “Commercial Series” models).
The date of purchase shall be determined by a dated sales receipt
noting the model and serial number of the pump. The dated sales
receipt must accompany the returned pump if the date of return is
more than three years from the date of manufacture noted on the
pump nameplate.
The manufacturer's sole obligation under this Warranty shall be
limited to the repair or replacement of any parts found by the
manufacturer to be defective, provided the part or assembly is
returned freight prepaid to the manufacturer or its authorized
service center, and provided that none of the following
warranty-voiding characteristics are evident:
The manufacturer shall not be liable under this Warranty if the
product has not been properly installed, operated, or maintained
per manufacturer instructions; if it has been disassembled,
modified, abused, or tampered with; if the electrical cord has been
cut, damaged, or spliced; if the pump discharge has been reduced
in size; if the pump has been used in water temperatures above
the advertised rating; if the pump has been used in water
containing sand, lime, cement, gravel, or other abrasives; if the
product has been used to pump chemicals, grease, or
hydrocarbons; if a non-submersible motor has been subjected to
moisture; or if the label bearing the model and serial number has
been removed.
Liberty Pumps, Inc. shall not be liable for any loss, damage, or
expenses resulting from installation or use of its products, or for
indirect, incidental, and consequential damages, including costs of
removal, reinstallation or transportation.
There is no other express warranty. All implied warranties,
including those of merchantability and fitness for a particular
purpose, are limited to three years from the date of purchase.
This Warranty contains the exclusive remedy of the purchaser,
and, where permitted, liability for consequential or incidental
damages under any and all warranties are excluded.
*Liberty Pumps, Inc. warrants StormCell
®
batteries for 1 year from
date of purchase, and warrants that pumps of its Commercial
Series are free from all factory defects in material and
workmanship for a period of 18 months from the date of
installation or 24 months from the date of manufacture,
whichever occurs first, and provided that such products are used
in compliance with their intended applications as set forth in the
technical specifications and manuals.
Crawl Space
Discharge
Ground level
Foundation
Backfill
Drain line
or weep tile
(optional)
Frost line