EasyManua.ls Logo

Liberty Pumps LGV02 Series User Manual

Liberty Pumps LGV02 Series
12 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Copyright © Liberty Pumps, Inc. 2022
All rights reserved.
Installation Manual
For pressure sewer applications, verify a Redundant
Check Valve Assembly (curb stop and check valve) is
installed between the pump discharge and the street
main, as close to the public right-of-way as possible, on all
installations to protect from system pressures.
Installer: manual must remain with owner or
system operator/maintainer.
Record information from pump nameplate:
Model:
Serial:
Control Panel:
Mfg Date:
Install Date:
Dealer:
Dealer Ph:
7000 Apple Tree Avenue
Bergen, NY 14416
ph: 1-800-543-2550
fax: 1-585-494-1839
www.LibertyPumps.com/LEP
60 Hz
5595000B
LGV02-Series
Single Stage
LGH02-Series
Two Stage
Ordinary Location Models
2.5 hp
Submersible
Grinder Pumps

Questions and Answers:

Liberty Pumps LGV02 Series Specifications

General IconGeneral
Pump TypeGrinder Pump
Horsepower2 HP
Impeller MaterialCast Iron
Housing MaterialCast Iron
PhaseSingle Phase
Construction MaterialsCast Iron

Summary

General Information

Operating Constraints

Inspection and Storage

Initial Inspection

Inspect pump and spare parts for damage and check electrical wires for damage, especially where they exit.

Model Specifications

Pump System Components

Control Panel

Describes requirements for control panels for LGH02/LGV02-Series pumps and wiring verification.

Wiring Instructions

Power and Control Cords

Details on power and control cords, including grounding and non-splicing requirements.

Thermostats

Overload Protection

Preparation

Install Pump Control and Alarm Floats

Guidance on positioning control floats for optimal pump cooling and operation.

Prepare Basin

Instructions for preparing the sump basin, cleaning debris, and inspecting existing equipment.

Cutter and Impeller Free Movement Check

Check for free movement of the cutter and impeller, emphasizing safety precautions.

Installation

Electrical Connections

Instructions for making electrical connections based on wiring diagrams.

3-Phase Pump Rotation Verification

Procedure to verify correct pump rotation for 3-phase models before installation.

Discharge Line

Pressure Sewer Applications

Requirements for redundant check valve assembly in pressure sewer systems.

Vent

Guide Rail Systems

Operation

Starting System

Maintenance and Troubleshooting

Maintenance

Routine checks for pump and system maintenance, including monthly, quarterly, and annual tasks.

Troubleshooting

Guidance on identifying and resolving common pump and system problems.

Warranty

Liberty Engineered Products Limited Warranty

Details the limited warranty period, coverage, and conditions for Liberty Engineered Products.

Related product manuals