11. TROUBLE SHOOTING GUIDE
Fault Code Main reason Solution
E01
The wire from the display to bottom
control board is not connected well
1
Check the connection wire between
computer and control board.
2 Make sure the IC on the control board
is properly connected. If not re-connect.
3 Abnormal power supply in control
board. Replace control board.
E02 Explosion protection
1
Bad contact with motor open circuit.
Replace motor or check the connector.
2 Power tube has been punctured.
Replace Power tube or control board.
E05 Over current Protection
1
Overloaded
2 Running board experiencing heavy
resistance. Need to be oiled
3 Damage to Motor. Replace motor.
E06 Control board self-checking
E08 EEPROM damage Replace the control board