7.3.5 Every 100 Operating hours
Check carburetor diaphragm of the Stromberg-Zenith carburetor.
Check magneto timing and adjust, if necessary.
Clean fuel pump screen.
Work as specified in section 7.3.4
7.3.6 Every 250 Operating hours
Disassemble and check magneto(s) and replace as necessary (SLICK Magnetos only).
Work as specified in section 7.3.4
7.3.7 Every 500 Operating hours
Disassemble and check magneto(s) and replace as necessary (BENDIX Magnetos only).
Replace float valve.
Check play of throttle shaft (L 2000 EB only).
Check valve shaft projecting length.
Work as specified in section 7.3.4