Initialisation of the DESKLINE
®
parallel system
The DESKLINE system is initialised by pressing the down button once or twice and holding it down until the DB/DL runs into
end stop. It will then automatically run approx. 3 mm out again and hereafter slowly run in again. Only release the down
button when the movement has stopped completely.
If the button is released before the sequence is completed, the initialisation is interuppted and must be started again
from the beginning.
The first two times the system runs into the outward end-stop, it will automatically run approx. 3 mm back in inward direction.
The CBD6S (SMPS) can control the DB/DL in 2-parallel, 3-parallel, 4-parallel or even multi-parallel.