Subject to modifications
Owner Manual
Operating Instructions
2.2A-10001-G07
LINCOLN GmbH • Postfach 1263 • D-69183 Walldorf • Tel +49 (6227) 33-0 • Fax +49 (6227) 33-259
Page 23 of 36
Planning and Layout, continuation
Instructions for Quicklub Progressive Systems, continuation
9. Lubricant output of the pumps 203* and 205**
at 100 bar backpressure
at 20°C
at 24 V rated voltage *
Pump element K5...................2 cm3/min*; 0.10 cm³/stroke**
Pump element K6................2.8 cm3/min*; 0.15 cm³/stroke**
Pump element K7...................4 cm3/min*; 0.22 cm³/stroke**
Adjustable pump element K7 ..........0.04 - 0.18 cm³/stroke* **
Lubricant output of the pump 215
Max. number of outlets....................................................15
Lubricant output per piston stroke:
Pump element piston dia. 6 mm ................................0.10 cm³
Pump element piston dia. 7 mm ................................0.23 cm³
Adjusting range...................................................25% to 100%
1001a96
Fig. 39 Dividing the lubricant quantity - Calculation example