Testing and Troubleshooting
233190 X3 Linear LLC 38 May 2013
Pressing the Revert button causes the controller to begin the revert process,
indicated by a blinking system status LED. You will hear the following beeps:
A triple beep indicating the factory defaults listed below have been restored.
A double beep indicating the controller is restarting.
A single beep indicating the revert process is complete, and you can login
using the default, out-of-box settings.
The revert process does the following:
Resets all controller network settings to their factory defaults:
o The IP address is reset to 192.168.0.250.
o The subnet mask is reset to 255.255.255.0.
o The gateway, DNS 1, and DNS 2 are each reset to 192.168.0.1.
Resets the web server port to port 80.
Resets the password for the default administrator account to admin.
Re-enables the administrator account, if necessary.
Reassigns full system administrator rights to the default administrator
account.
Resets the interface language to English.
Note: Once the controller network and login factory defaults have been reset,
you can change them at any time by selecting Setup : Site Settings :
Network Controller. Click the Initmode link to change the network
settings and the web server port number. Click the Localization link to
change the interface language.