EasyManua.ls Logo

Linear eMerge 50P - Readers; Cameras

Linear eMerge 50P
47 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Hardware and Third-Party Device Specifications
233190 X3 Linear LLC 40 May 2013
Readers: Twisted, shielded 22 AWG Belden #9536 (6 conductor) or
equivalent.
Maximum distance from a reader to the eMerge system: 500 feet (152
meters).
Temperature Sensors (not evaluated by UL): Up to 500 feet (152 meters)
twisted Category 3; Over 500 feet up to 1000 feet (305 meters) twisted
Category 5.
Maximum distance from a temperature sensor to the eMerge system: 1000
feet (305 meters).
Diodes required for output devices that are DC powered: 1N4002- 1 A, 50 V,
Fast Recovery Diode or equivalent.
Varistors (MOV) required for output devices that are AC powered: 40 VAC,
56 VDC, 10 A Surge, Radial Leaded Varistor or equivalent, such as World
Products Inc. SNR-D56K2.
Resistors required for input devices: 1k Ohms.
Ethernet cable: CAT 5 cable or better with RJ-45 connector.
Readers
The eMerge system’s access control blade supports card readers that use the UL
listed 26 bit, 126 bit, and 200 bit Wiegand Reader Interface.
Cameras
Cameras have not been evaluated by UL.
The controller supports up to 128 cameras. The exact number will depend on
usage. IP video cameras may be connected directly to the network and driven by
the controller. For UL application, IP cameras were not investigated.
At this release, the controller is tested to work with the following camera models:
Axis: All VAPI-compliant cameras and models 2120, 232D
IQinVision: Various IQeye models
Panasonic: Models WV-NM100, WV-NS324
Sony: Models SNC-DF40N/DF40P, SNC-P1, SNC-RZ30N
Vivotek: Model IP2111

Table of Contents