ڦ Connect to RS-232C
Connect RS-232C connectors of the target devices to the RS-232C port of
analyzer using monitor cable.
ڧ For monitoring
ڧ For Simulation
Connect analyzer and target device
one by one.
Connect as following, concerning
the specification of target device
(DTE/DCE) and RS-232C cable.
If the connector of either target
device is Dsub 25 pin, use attached
Dsub 25 pin monitor cable (LE-
25M1) to connect to the analyzer.
If the connectors of both target devices
are Dsub 9 pin, use attached Dsub 9
pin monitor cable (LE-009M2) and
Dsub 25-9 conversion adapter to
connect to the analyzer.
Dsub25
Either is Dsub 25
pin connector
MONITOR Cable
RS-232C Port
Dsub25-9
(conversion
adapta)
Both Dsub 9 pin
connector
Dsub9
MONITOR Cable
(for Dsub 9pin)
RS-232C Port
RS-232C Cable
RS-232C Port
Dsub25
DTE device -----Straight cable -----Analyzer (DCE setting)
DCE device -----Straight cable -----Analyzer (DTE setting)
DTE device ------ Cross cable -------Analyzer (DTE setting)