163
Chapter 10: Troubleshooting
Free Bound Aggregation Storage when the Master Sys-
Network Storage System (NSS) Administrator Guide
Chapter
10
Free Bound Aggregation Storage when the Master System
Fails
Problem Scenario: A storage system is bound to a failed storage system and rejects any bind requests
from other systems. The steps to recreate this problem are as follows:
1. Export storage from System A.
2. Import storage from System A to System B.
3. System B crashes and cannot be recovered.
4. System A is "bound" to System B and rejects any new bind requests from other systems.
Resolution: To resolve the problem:
1. Unexport the bound storage system (in our example, System A).
2. Re-export the storage system.
The storage system is now available to be used by another system.