18
lippert.com 432-LIPPERT (432-547-7378) Rev: 10.14.21
Ground Control
®
3.0
5th Wheel Leveling Prepped Unit
to Full Automatic Leveling
Installation and Owner’s Manual
(For Aftermarket Applications)
CCD-0004397
LCD MessageLCD Message What is happening?What is happening? What should be done?What should be done?
****ERROR****
Excess Angle
Controller not properly secured. Check and secure controller placement.
Excessive angle reached during auto operation. Relocate the trailer.
****ERROR****
Excessive Angle
Controller not properly secured. Check and secure controller placement.
Excessive angle reached during manual
operation.
Relocate the trailer.
****ERROR****
Low Voltage
Battery voltage dropped below 10.8V.
Check wiring - repair or replace.
Test battery voltage under load - charge or replace.
****ERROR****
Out Of Stroke
Jack has reached maximum stroke length and
is unable to lift.
Check disposition of jacks. Relocate the trailer.
Unexpected high amp current stall.
Check jacks in manual mode or perform manual
override procedure. Repair or replace as needed.
Check for bent or damaged jacks. Repair or
replace as needed.
****ERROR****
External Sensor
Bad connection or wiring from the controller to
the rear sensor.
Replace or repair connection to rear remote sensor.
****ERROR****
Jack Time Out
Time limit exceeded for the requested auto
operation.
Check disposition of jacks.
****ERROR****
Auto Level Fail
Unable to auto level due to uneven ground. Check disposition of jacks. Relocate the trailer.
Unable to auto level due to zero point being
set incorrectly.
Reset zero point.
****ERROR****
Comm Error
Communication between the controller and touch
pad has been lost.
Check harness for proper connections or damage.
Repair or replace as needed.
****ERROR****
Bad Calibration
Sensor calibration values are out of range. Replace controller.
****ERROR****
Internal Sensor
Internal sensor problem. Replace controller.
**PANIC STOP**
Function Aborted
The user pressed a button on the touch pad
during an automatic operation.
Restart automatic operation and then refrain from
pressing any buttons on the touch pad.
***ERROR****
Hall Effect Short
Short circuit detected in one of the hall effect circuits. Test for short. Repair or replace as needed.
NOTE: To clear an error from the touch pad, repair or otherwise correct the issue, then press “ENTER”. If the error is still
present, the message will be displayed again.
LCD Error Codes