78 
 
  L1-00    to    L1-15 Frequency Command 1 to 16 and L1-16 Jog Frequency Command   
The  drive  allows  the  user  to  switch  between  up  to  16  frequency  commands  and  1  Jog 
frequency command. The    drive    uses the selected acceleration and deceleration times when 
switching between each frequency command.   
The Job frequency command overrides frequency command 1 to 16.   
Frequency Command   
1 to 16 
L1-00 5.00Hz 
L1-01 8.00Hz 
L1-02 10.00Hz 
L1-03 12.00Hz 
L1-04 15.00Hz 
L1-05 20.00Hz 
L1-06 25.00Hz 
L1-07 30.00H7 
L1-08 35.00Hz 
L1-09 40.00Hz   
L1-10 42.00Hz 
L1-11 45.00Hz 
L1-12 50.00Hz 
L1-13 50.00Hz 
L1-14 50.00Hz 
L1-15 50.00Hz 
<1> The upper limit is determined by d1-02 (Maximum Output Frequency) and L2-00 (Frequency Command Upper 
Limit).   
<2> If L2-00 (Frequency Upper Limit) is adjusted, the excessive frequency in L1-00 to L1-15 will be automatically 
set to the upper limit determined in L2-00. 
□  Setting Multi-Step Speed 
To  assign  a  multi-step  speed  command  to  a  multi-function  input,  set  E1-□□=  5,  6,  7,  8 
(Multi-Step Speed 1, 2, 3, 4). To assign the Jog frequency command to a multi-function input, 
set E1-□□ =9.   
Table 6.12 Multi-Step Speed Command and Multi-Function Terminal Combinations 
Multi-Step 
Speed 
Command 1 
E1-□□=5 
Multi-Step 
Speed 
Command 2 
E1-□□=6 
Multi-Step 
Speed 
Command 3 
E1-□□=7 
Multi-Step 
Speed 
Command 4 
E1-□□=8 
Multi-Step 
Speed 
Command 5 
E1-□□=9