Gocator Line Profile Sensors: User Manual
Gocator Device Files 435
<Output>
<Ethernet>
...
<Ranges options=""/>
<Profiles options="0,1">0</Profiles>
<Surfaces options=""/>
...
Element Type Description
Protocol 32s
Ethernet protocol:
0 Gocator
1 Modbus
2 EtherNet/IP
3 ASCII
TimeoutEnabled Boolean Enable or disable auto-disconnection timeout. Applies only to the
Gocator protocol.
Timeout 64f Disconnection timeout (seconds). Used when TimeoutEnabled is true and
the Gocator protocol is selected.
Ascii Section
See Ascii on page 437.
EIP Section
See EIP on page 437.
Modbus Section
See Modbus on page 437.
Videos 32s (CSV)
Selected video sources:
0 Top
1 Bottom
2 Top left
3 Top right
Videos.options 32s (CSV) List of available video sources (see above).
Ranges 32s (CSV)
Selected range sources:
0 Top
1 Bottom
2 Top left
3 Top right
Ranges.options 32s (CSV) List of available range sources (see above).
Profiles 32s (CSV)
Selected profile sources:
0 Top
1 Bottom
2 Top left
3 Top right
Ethernet Child Elements

Table of Contents