EasyManua.ls Logo

LMI Technologies Master 810 - Page 628

Default Icon
652 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Gocator Line Profile Sensors: User Manual
Specifications 629
Specification Value
Power Draw (Min.) 5.76 W
Safety Input Voltage Range +24 VDCto +48 VDC
Encoder Signal Voltage Differential (5 VDC)
Digital Input Voltage Range Logical LOW: 0 to +0.1 VDC
Logical HIGH: +3.3 to +24 VDC
When using a Master hub, the chassis must be well grounded.
The power supply must be isolated from AC ground. This means that AC ground and DC ground
are not connected.
The Power Draw specification is based on a Master with no sensors attached. Every sensor has
its own power requirements that need to be considered when calculating total system power
requirements..