Service Manual
Models: 400 - 1000
Series 100 & 101
This manual must only be used by
a qualified heating installer / service
technician. Read all instructions,
including this manual and the Armor
Installation and Operation Manual,
before installing. Perform steps in the
order given. Failure to comply could
result in severe personal injury, death,
or substantial property damage.
󰖱 WARNING
Save this manual for future reference.
100332297_2000589045_Rev A
LOW LEAD CONTENT
Question and Answer IconNeed help?

Do you have a question about the Lochinvar AWH1000NPM and is the answer not in the manual?

Lochinvar AWH1000NPM Specifications

General IconGeneral
ModelAWH1000NPM
CategoryWater Heater
Fuel TypeNatural Gas
Minimum Water Supply Pressure (psi)30
Maximum Water Supply Pressure (psi)150
Vent Diameter (inches)3
MaterialStainless Steel
Capacity1000 gallons

Summary

Important Safety Precautions

Pre-Installation and Servicing Guidelines

Emphasizes reading all instructions before installation and service.

1 Service: Control Parameters

1 Service: Initial Setup

1 Service: Control Modes

1 Service: Cascade Setup

1 Service: Circulation Pumps and Notifications

2 Maintenance: Schedules

2 Maintenance: Component Checks

2 Maintenance: System Checks

2 Maintenance: Heat Exchanger

Cleaning the Heat Exchanger

Provides detailed steps for cleaning the water heater's heat exchanger.

3 Troubleshooting: Preparation

General Troubleshooting Warnings

Provides essential safety warnings before performing troubleshooting.

3 Troubleshooting: Faults

Troubleshooting Chart: No Display

Lists causes and corrective actions for a blank display.

Troubleshooting Chart: Noisy System

Lists causes and corrective actions for noisy operation.

Troubleshooting Chart: No Burner Operation

Addresses faults related to the burner not operating.

Troubleshooting Chart: No Pump Operation

Addresses faults related to the pump not operating.

3 Troubleshooting: Sensors

Checking Temperature Sensors

Explains how to check sensors using resistance tables.

3 Troubleshooting: Fault Messages

Troubleshooting: Gas Pressure Switch Fault

Corrective actions for gas pressure switch faults.

Troubleshooting: Anti-cycling Fault

Explains the anti-cycling fault and its resolution.

Troubleshooting: No Flame Running Fault

Covers faults where the unit loses flame signal during operation.

Troubleshooting: Flame Sequence Fault

Addresses faults where flame is detected without actual flame.

Troubleshooting: Fan Speed Low Fault

Addresses faults when fan RPM is lower than expected.

Troubleshooting: Sensor Shorted Fault

Corrective actions for shorted temperature sensors.

Troubleshooting: Outlet Temp High Fault

Corrective actions for exceeding maximum outlet water temperature.

Troubleshooting: Low 24 VAC Input Fault

Corrective actions for low 24 VAC input to the main control board.

Troubleshooting: Flow Switch Fault

Corrective actions for flow switch faults.

Troubleshooting: Flame Fail Ignition Fault

Addresses faults when main burner ignition fails.

Troubleshooting: Auto Reset High Limit Fault

Corrective actions for auto reset high limit faults.

Troubleshooting: Fan Speed High Fault

Addresses faults when fan RPM is higher than expected.

Troubleshooting: Control Board Internal Faults

Addresses various internal fault messages for the main control board.

Troubleshooting: Blocked Drain Switch Fault

Corrective actions for blocked drain switch faults.

Troubleshooting: Manual Reset High Limit Fault

Corrective actions for manual reset high limit faults.

Troubleshooting: Sensor Open Fault

Corrective actions for disconnected temperature sensors.

Troubleshooting: Flue Temp High Fault

Corrective actions for high flue temperature faults.

Troubleshooting: Service Block Fault

Covers faults when unit exceeds temperature in service mode.

Troubleshooting: Air Pressure Switch Fault

Corrective actions for air pressure switch faults.

Troubleshooting: Delta T High Fault

Addresses faults related to high temperature rise across the heat exchanger.

3 Troubleshooting: Combustion

Check Flame and Combustion Analysis

Guides on performing combustion analysis and checking flame.

Combustion Levels Troubleshooting

Details causes and corrective actions for combustion level issues.