26
TECHNISCHER KUNDENDIENST
12 CI Interface
MB180 Digital CI ve Smart Card Interface Block diagram:
13 DVB-T / T2 / C Demodulator (CXD2820R)#
The Sony CXD2820R is a combined DVB-T2, DVB-T and DVB-C demodulator that
conforms to the ETSI EN 302-755 (second generation Terrestrial) ETSI EN 300-744
(Terrestrial) and ETSI EN 300-429 (Cable) standards.
The CXD2820R is a DVB-T2 demodulator offering class-leading performance,
optimised
BOM requiring no external memory and low processor overhead. It includes a highly
integrated dual-core DVB-T and DVB-C demodulator which complies with all relevant
European performance standards.
Loewe Opta GmbH
96317 Kronach, Industriestr. 11
Telefon (0 92 61) 99-0
Telefax (0 92 61) 99-730
e-mail: hotel-service@loewe.de
www.loewe.de
Seite 14 von 24 Stand: 26.01.2012
DVB-T / T2 / C Demodulator (CXD2820R)#
The Sony CXD2820R is a combined DVB-T2, DVB-T and DVB-C demodulator that conforms to
the ETSI EN 302-755 (second generation Terrestrial) ETSI EN 300-744 (Terrestrial) and ETSI EN
300-429 (Cable) standards.
The CXD2820R is a DVB-T2 demodulator offering class-leading performance, optimised BOM
requiring no external memory and low processor overhead. It includes a highly integrated dual-
core DVB-T and DVB-C demodulator which complies with all relevant European performance
standards.
TECHNISCHER KUNDENDIENST
14 LNB supply and control IC
Intended for analog and digital satellite receivers, the LNBH23L is a monolithic voltage
regulator and interface IC, assembled in QFN32 5 x 5 specifically designed to provide
the 13 /
18 V power supply and the 22 kHz tone signalling to the LNB down-converter in the
antenna
dish or to the multi-switch box. In this application field, it offers a complete solution with
extremely low component count, low power dissipation together with simple design and
I²C
standard interfacing.
Loewe Opta GmbH
96317 Kronach, Industriestr. 11
Telefon (0 92 61) 99-0
Telefax (0 92 61) 99-730
e-mail: hotel-service@loewe.de
www
.loewe.de
Seite 15 von 24 Stand: 26.01.2012