Injector Size Table
Burner Injector Values According To The Gas Type.
Destination: GB Gas Category II
2H3+
LPG Natural Gas
G 30/31
28-30/37 mBar
G 20
20 mBar
All intervention regarding installation maintenance and conversion of the appliance must be
fulfilled with original factory parts.
The manufacturer declines any liability if these correct parts are not used.
Large Burner (Fast)
Injector mm 0.850 1.150
Gas Flow
(15°C and 1013mbar)
210.90 gr/h 276.20 lt/h
Power kW 2.90 2.90
Standard Burner
Injector mm 0.650 0.970
Gas Flow
(15°C and 1013mbar)
120.00 gr/h 166.70 lt/h
Power kW 1.65 1.75
Small Burner (Simmer)
Injector mm 0.500 0.720
Gas Flow
(15°C and 1013mbar)
65.40 gr/h 95.20 lt/h
Power kW 0.90 1.00
Multi Burner
Injector mm 0.960 1.300
Gas Flow
(15°C and 1013mbar)
261.70 gr/h 342.80 lt/h
Power kW 3.60 3.60
Total Power kW 9.05 9.25
LFTG90W14_IB.indd 31 09/02/2015 17:51