- 59 -10.13
Code Error description Note Rectication
E16 Supply voltage
motor and main
contactor
Internal supply voltage is too little
(42V~ / 60V-) /
PE conductor monitoring input
(Fault current to protective earth
conductor)
Check power supply
voltage /
Check con-
nection of the workpiece
cable and ground clip,
check for short-circuits
between welding wire
and housing
E17 Peripherie overload/
short circuit
Short circuit in torch or hose pack-
age, gas valve or feed line, wire
run key or line
Test alt. exchange the
connected torch
E18 Error conguration Faulty or wrong pc-board,
wrong software system played
Inform Service
Tab. 1: Messages