Technical data
- 63 -10.13
Technical data
1
M 200 CuSi M 250 M 300
Usable wires CrNi
Ø mm 0,8..1,0 0,8..1,0 0,8..1,2
Usable wires CuSi
Ø mm 0,8..1,0 - -
Wire feed rate m/min 0,5..25 0,5..25 0,5..25
Mains
Mains voltage 3~ (50/60 Hz)
V 3~ 400 3~ 400 3~ 400
Positive mains voltage tolerance
% 15 15 15
Negative mains voltage tolerance
% 25 25 25
Input power S1 (100 %)
kVA 2,7 3,7 4,5
Input power S1 (60 %)
kVA 4,0 4,5 5,7
Input power S1 (max current)
kVA 7,3 9,8 13,4
Current input I1 (100 %)
A 3,9 5,3 6,5
Current input I1 (60 %)
A 5,4 6,5 8,2
Current input I1 (max. current)
A 10,6 14,2 19,3
Maximum effective mains current
(I
1eff
)
I
1eff
/A 4,7 6,4 8,6
Power factor (at 12max)
cos φ 0,89 0,89 0,89
Mains fuse (slow-response)
A 16 16 16
Mains plug
CEE 16 CEE16 CEE16
Machine
Protection class (in accord-ance with
EN 60529)
IP 23S 23S 23S
Insulation class F F F
Cooling method F F F
Noise emission dB(A) < 70 < 70 < 70
Dimensions and weights
Dimensions mm 880 x 400 x 755 880 x 400 x 755 880 x 400 x 755
Weight kg 74 71 80
Standard equipment
Feed unit Rollers 4 4 4
Tab. 3: Technical data
1
) measured at 40° C environmental temperature
2