Chapter 7. Usage of Various Functions
7-109
10) Synchronization control (POSSYNC)
Function block Description
Input
REQ : Execute POSSYNC function block
CH: Sets the channel (0 ~ 1)
HSC_CH: Sets POSSYNC input channel (0~3)
SCALE: Sets the scale (0 ~ 100%)
Output
DONE: Turns On after the function block is executed without error, and
turns Off if an error occurs or there is no execution command.
STAT: Displays error status
(1) Functions
When input condition turns on, the designated channel at the rising edge executes the synchronization control by specified scale.
(2) Example program
When the input condition (%MX000) turns on, Ch. 0 operates synchronization control by 30% of HSC Ch. 0’s speed.