8-56
• It sends Frame 0 by operating the function block every 200m.
• Frame 0 sends 4-byte value from %MBO of the master station.
• Frame 1 is saved in %MB10 (refer to frame setting of Frame 1), and the saved %MB10 value is reversed and outputted
at %QB0.0.0. The output value of %QB0.0.0 is saved again in %MB0.
• When 8 LED of the master are on, then 8 LED of the slave are off, and vice versa.
• ‘Enable Link’ must be set for master and slave.