14. Specifications
14-1
SV-iC5
14. Specifications
14.1 Technical data
Input & output ratings
Model : SV xxx iC5 – 2x 004 008 015 022
Max motor capacity
1
[HP] 0.5 1 2 3
[kW] 0.4 0.75 1.5 2.2
Output
ratings
Capacity [kVA]
2
0.95 1.9 3.0 4.5
FLA [A] 2.5 5 8 12
Frequency 0 ~ 400 [Hz]
3
Voltage Three Phase 200 ~ 230V
4
Input
ratings
Voltage
Single Phase 200 ~ 230V (±10%)
Frequency
50 ~ 60 [Hz] (±5%)
Current 5.5 9.2 16 21.6
Control
Control mode V/F control, Sensorless vector control
Frequency setting resolution
Digital: 0.01Hz
Analog: 0.06Hz (Max. frequency : 60Hz)
Accuracy of Frequency command
Digital: 0.01% of Max. output frequency
Analog: 0.1% of Max. output frequency
V/F Ratio Linear, Squared Pattern, User V/F
Overload capacity Software: 150% for 60 s
Torque boost Auto/Manual torque boost
Operation
Operation mode Keypad/ Terminal/ Communication option selectable
Frequency setting
Analog: 0 ~ 10[V], 0 ~ 20[mA], Keypad Potentiometer
Digital : Keypad
Operation features PID control, Up-Down operation, 3-wire operation
Input
Multi-function terminal
NPN/ PNP selectable
Function: (refer to page 3-5)
Output
Multi-function open
collector terminal
Operating status Function: (Refer to page 11-6)
1
Indicates the maximum applicable motor capacity when using a 4-pole standard motor.
2
Rated capacity is based on 220V.
3
Max settable freq is 300Hz when H30 is set to 3 “Sensorless Vector Control”.
4
Max output voltage will not be greater than the input voltage. Output voltage less than the input voltage can be
programmed.