LTSscale.com Page 16 of 28 REV F ā 2018.04.09
INCREMENTS
Display shows:
Standard Values for Number of increments are:
Press DEL key to select increments value.
Press ENTER key to accept setting.
Displays shows capacity, plus the count-by factor.
Example:
Count by factor: = 5
Decimal positioning value: = 0
Increments: = 1000
2500 (increments) x 2 (count-by) = 5000
Display shows: 5005
If the capacity and count-by factor are correct then, press ENTER key to accept these
settings. If not press DEL, and return to the beginning.
LEGAL FOR TRADE
Press DEL key to select YES or NO.
Press ENTER key to accept setting.
If set to YES, further calibration will be disabled until the back cover is removed to access
the calibration switch.
SELECT MOTION
Available motion settings are:
Legal-for-Trade = YES: 1 2 3
Legal-for-Trade = NO: 1 2 3 4 5 6 7 8 9
Press DEL key to select motion setting.
Press ENTER key to accept setting.
MOTION DELAY
Available motion delay settings are:
0.5 1.0 1.5 2.0 2.5 3.0
Press DEL key to select the motion delay setting.
Press ENTER key to accept setting.
Note: an analog filter is available on the main board. Potentiometer (R19) is
located at the bottom left-hand corner of the main board. Adjusting this
potentiometer may require re-calibration after adjustment. Counterclockwise
will slow the update rate while clockwise will speed the rate up.
DISPLAY MOTION
YES Weight is displayed during motion conditions.
NO Weight is only displayed when within the motion band.
Press DEL key to select YES or NO.
Press ENTER key to accept setting.
DISPLAY ON TOP LINE
YES Motion is displayed on top line
NO Motion is not displayed on top line
SELECT INCREMENT
NUMBER = 1000
SELECT MOTION #D
NUMBER = 1
SELECT MOT DELAY
SECONDS = 1.0