EasyManuals Logo

Lucent Technologies MERLIN LEGEND Release 6.1 Pocket Reference

Lucent Technologies MERLIN LEGEND Release 6.1
164 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #22 background imageLoading...
Page #22 background image
MERLIN LEGEND Communications System Release 6.1
Pocket Reference
555-661-116
Issue 1
August 1998
Page 16
Release 4.0 Enhancements (March, 1996)
Equipment
New hardware includes two new modules. They are:
An 016 (T/R) module supporting 16 tip/ring devices and four
TTRs. All 16 ports can ring simultaneously. The module’s
ringing frequency (factory setting 20 Hz) can be changed
through programming to 25 Hz for those locations that require it.
An 800 NI-BRI module supporting high-speed data and video
transmission.
Maintenance Support
The R4.0 software includes a Provisioning Test tool that
technicians can use to verify the operational status of installed
NI-1 BRI lines.
User Features
Product Enhancements
The following enhancements are added:
Delay Call Forwarding. Each user can program a Forwarding
Delay setting for calls that are forwarded using Forward,
Remote Call Forwarding, or Follow Me. The forwarding delay is
the number of times a call rings at the forwarding extension
before the call is sent to the receiver. During the delay, the user
may screen calls by checking the displayed calling number (if it
is available). The delay can be set at 0 to 9 rings. The factory
setting for Forwarding Delay is 0 rings (no delay).
Voice Announce on the QCC. The QCC operator can use the
fifth Call Button to announce a call on another user’s
speakerphone if the destination telephone has a Voice
Announce-capable SA button available. QCCs cannot receive
Voice Announce calls; they are received as ringing calls. The
factory setting for the fifth Call button is Voice Announce
disabled.
Timebased option for overflow on Calling Group. If the
Overflow Threshold Time is set to a value between 1-900
seconds, calls that remain in the Calling Group Queue for the
set time are sent to the Overflow Receiver. This is in addition to
the number of calls that are in the Queue (previously, the only
way to send calls to the Overflow Receiver). If the Overflow
Threshold Time is set to 0, Overflow by time is off. The factory-
set time limit is 0 (overflow by time is off).
Downloadable Firmware for 016 T/R board and the NI-BRI
board. The PCMCIA technology introduced in Release 3.0
continues to support these two new boards in Release 4.0 for
installation and upgrade. A Release 3.0 or later processor is
required for PCMCIA technology.
Single-Line Telephone Enhancements
The following enhancements are added to the single-line
telephones:
Disable Transfer. Through centralized programming, the
system manager can disable the ability to transfer calls by
removing all but one SA or ICOM button from the telephone.

Other manuals for Lucent Technologies MERLIN LEGEND Release 6.1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lucent Technologies MERLIN LEGEND Release 6.1 and is the answer not in the manual?

Lucent Technologies MERLIN LEGEND Release 6.1 Specifications

General IconGeneral
BrandLucent Technologies
ModelMERLIN LEGEND Release 6.1
CategoryConference System
LanguageEnglish

Related product manuals