EasyManuals Logo

Lucent Technologies MERLIN LEGEND Release 6.1 Pocket Reference

Lucent Technologies MERLIN LEGEND Release 6.1
164 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #97 background imageLoading...
Page #97 background image
MERLIN LEGEND Communications System Release 6.1
Pocket Reference
555-661-116
Issue 1
August 1998
Page 91
Power Supply Unit Load Requirements
Power Supply Unit Load Requirements
(continued)
Unit Load Rating of System Modules
* 012 modules older than 517H13 may have a unit load up to 8.4.
This is a MERLIN II loop-start-only module that can be used in the MERLIN
LEGEND Communications System.
Module Unit Load Module Unit Load
008 12.0 408 GS/LS 12.0
008 MLX 13.5 408 GS/LS-MLX 12.0
008 OPT 8.0 408 (LS) 12.0
012 T/R 7.2* 800 GS/LS 0.0
016 T/R 12.8 800 GS/LS-ID 0.0
100D (DS1) 0.0 800 (LS)† 0.0
400 GS/LS/TTR 0.0 800 DID 8.0
400 (LS)
0.0 800 NI-BRI 0.0
400EM 8.0 Processor 0.0