  Chapter 9 Installation  16 
9.3  Selecting the Installation Location 
In order to guarantee long service life and correct equipment operation, please pay attention to 
the following points when selecting the installation location. 
9.3.1  General Instructions 
  Stable subsurface for installing the mast 
  Free access to the equipment for maintenance works 
  Reliable power supply for permanent operation 
  Good network coverage when transmitting over a mobile communications network 
 
Note: The computed measurements specifically apply to the equipment location only. No 
conclusions can be drawn with regard to the wider environment or a complete road section. 
 
ATTENTION: 
  Only approved and tested appliances (conductors, risers etc.) should be used to install 
  the device on the mast. 
  All relevant regulations for working at this height must be observed. 
  The mast must be sized and anchored appropriately. 
  The mast must be earthed in accordance with regulations. 
  The corresponding safety regulations for working at road side and in the vicinity of the 
  road carriageway must be observed. 
 
If the equipment is installed incorrectly 
  It may not function. 
  It may be permanently damaged. 
  Danger of injury may exist if the equipment is allowed to fall. 
9.3.2  Installation of Ventus 
  Installation at the top of the mast 
  Installation height at least 2m above the ground 
  Free field around the sensor 
 
Note: Buildings, bridges, embankments and trees may corrupt the wind measurement. Equally, 
passing traffic may cause gusts which may influence the wind measurement.