Operating Manual V25/09.2019
Ventus / Ventus-X / V200A
Chapter 20 Appendix 51
20.5.10 Baud Rate
Description: This command sets baud rate and parity.
Note: The switchover is effective after the next reset. To activate the new settings a reset must
be initiated by reset command or by briefly disconnecting the sensor from the power supply.
Request: <ID>‚‘BD’<value>(CR)
<ID> Device address (2 decimal places with leading zeros)
<value> baud rate / parity code (see table below)
The current setting is delivered as the response if no entry is made for <value>.
Response: !<ID>‘BD’<value>(CR)
Table of Baud Rate Codes
Code
Baud Rate
Parity
0
reserved
1
reserved
2
1200
8N1
3
2400
8N1
4
4800
8N1
5
9600
8N1
6
19200
8N1
7
38400
8N1
8
57600
8N1
9
reserved
10
1200
7E1
11
2400
7E1
12
4800
7E1
13
9600
7E1
14
19200
7E1
15
38400
7E1
16
57600
7E1
17
reserved
20.5.11 Response Delay
Description: This command sets the response delay after NMEA requests.
Request: <ID>‚‘RD’<value>(CR)
<ID> Device address (2 decimal places with leading zeros)
<value> 0 … 1000 delay time in msec
The current setting is delivered as the response if no entry is made for <value>.
Response: !<ID>‘RD’<value>(CR)