Operating Manual V25/09.2019
Ventus / Ventus-X / V200A
Chapter 20 Appendix 69
Reg.
No.
Reg.
Addr.
Value (UMB-
Channel)
Range
Scaling,
signed/unsigned,
remarks
Status information
1
0
Identification
High Byte: Device Subtype
LowByte: Software Version
2
1
Device status
Device status unequal 0 indicates
a serious problem when reading
the configuration storage or
during system start. Please
contact Lufft Service with
reference to the indicated code.
3
2
Sensorstatus 1
Air temperature buffer, air
temperature, air pressure buffer,
air pressure (High byte -> low
byte, see table below)
Coding 4 bit per
status, s. below
4
3
Sensorstatus 2
Windbuffer, wind (high byte, see
table below)
Coding 4 bit per
status, s. below
5
4
Reserved
6
5
Reserved
7
6
Reserved
8
7
Reserved
9
8
Reserved
10
9
Diagnostics: run time in 10sec
steps
Reg.
No.
Reg.
Addr.
Value (UMB-
Channel)
Range
Scaling,
signed/unsigned,
remarks
Values Independent of the Unit System
11
10
305
Rel. Air Pressure (act.)
Factor 10, s
12
11
325
Rel. Air Pressure (min.)
Factor 10, s
13
12
345
Rel. Air Pressure (max.)
Factor 10, s
14
13
365
Rel. Air Pressure (avg.)
Factor 10, s
15
14
500
Wind Direction (act.)
Factor 10, s
16
15
520
Wind Direction (min.)
Factor 10, s
17
16
540
Wind Direction (max.)
Factor 10, s
18
17
580
Wind Direction (vct.)
Factor 10, s
19
18
805
Wind Measurement Quality
Factor 1, s