Operating Manual    Smart Weather Sensor 
  G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany  41 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
11  Firmware Update 
To keep the sensor in accordance with the latest state-of-the-art, it is possible to carry out a 
firmware update on site with no need to remove the sensor and return it to the manufacturer. 
The firmware update is carried out with the aid of the UMB-Config-Tool. 
The description of the firmware update can be found in the instructions for the UMB-Config-
Tool. Please download the latest firmware and UMB-Config-Tool from our website 
www.lufft.com and install it on a Windows
®
 PC. You can find the instructions here:  
 
 
Note: When a firmware update takes place, under certain circumstances the absolute 
precipitation quantities are reset (channel 600 – 660). 
There is one firmware for the entire product family which supports all models 
(WSx_Release_Vxx.mot). 
Important Note: please read the included text file in WSx_Release_Vxx.zip; it contains 
important information about the update! 
12  Maintenance 
In principle the equipment is maintenance-free. 
 
However, it is recommended to carry out a functional test on an annual basis. When doing 
so, pay attention to the following points: 
  Visual inspection of the equipment for soiling 
  Check the sensors by carrying out a measurement request 
  Check the operation of the fan (not on WS200-UMB) 
 
In addition, an annual calibration check by the manufacturer is recommended for the 
humidity sensor (not on WS200-UMB). It is not possible to remove or replace the humidity 
sensor. The complete Smart Weather Sensor must be sent to the manufacturer for testing. 
 
Cleaning of the glass dome at regular intervals is suggested for devices with global radiation 
measurement. The length of the interval should be adapted to the local degree of pollution. 
 
Devices with precipitation measurement by rain gauge (WS401-UMB, WS601-UMB): The 
rain gauge funnel needs to be cleaned at regular intervals (see below). The length of the 
interval should be adapted to the local degree of pollution. 
 
Devices with leaf wetness sensor: Cleaning of the leaf wetness sensor at regular intervals is 
suggested. The length of the interval should be adapted to the local degree of pollution. A 
check and, if necessary, adjustment of the “Wet” threshold is recommended to include into 
the maintenance procedure.