19
10. Troubleshooting
Fault Check Cause Solution
Cylinderdoesnot
extend,extendstoo
slowlyorstopswhen
extending.
Checkthe
hydraulicuidlevel
inthehandpump
supplyingtheuid.
Insucient
hydraulicuidin
thehandpump.
Rellthehydraulicuid.
Checkthatthe
pressurerelief
valveonthehand
pumpisclosed.
Pressurerelief
valveonthehand
pumpopen.
Closethepressurerelief
valveonthehandpump.
Checkthatall
couplingsarefully
tightened.
Hydrauliccoupling
loose.
Tightenhydraulic
coupling.
Airinhydraulic
system.
Venthydraulicsystemin
accordancewith
section6.1.
Checkthecylinder
fordamage.
Cylinderpiston
jams.
Havethedamage
repairedbyanauthorised
dealer,bypersonnel
speciallytrainedby
LUKAS,orbyLUKAS
itself.
Cylinderextends,but
doesnotmaintainthe
pressure.
Checkthatall
connectionsare
fullytightened.
Leakyconnection. Tightenlooseconnection.
Checkthecylinder
forleaks.
Leakingseals. Havetheleaksrepaired
byanauthoriseddealer,
bypersonnelspecially
trainedbyLUKAS,orby
LUKASitself.
Internalleakageof
thehandpump.
Havethehandpump
servicedbyanauthorised
dealer,bypersonnel
speciallytrainedby
LUKASorbyLUKAS
directly.