8 TROUBLESHOOTING
LUMINELL SWEDEN AB 55
8 TROUBLESHOOTING
8.1 HOW TO IDENTIFY AND SOLVE PROBLEMS
Troubleshooting by non-skilled persons
Panel is showing “starting
system” with Luminell logo
and a blue flashing halo
around the control wheel
but not possible to control
movement or light
functions.
This is the initial system
boot-up sequence after the
searchlight has been
without power.
During this period, the
searchlight and panel
establish connection.
Searchlight will also run the
homing calibration by
moving both horizontal and
vertical axis. After homing is
ready the panel boot screen
will change to control mode
and be available for user.
Wait 20 second for the boot
sequence to finish before
operating the panel.
If the boot screen remains
longer than a minute:
1. Verify that the
searchlight is powered
and not only the panel.
2. Check the ethernet
cabling between the
searchlight and the
panel, bad connection?
Bad external switch (if
any)?
I Have started sync and
now I cannot get back to
the “Homesceen”
This is a normal behavior to
avoid starting automatic
functions such as sweep,
surveillance that is not
supported in sync mode.
First turn off sync in “NET-
screen” to access other
screens.