16
Internal
15: Inverter voltage calibration
Interface Setting
Parameter 2: you may choose Add or Sub to calibrate inverter
voltage
Parameter 3: The voltage setting range is from 0V to 6.4V. The
default value is 0V.
16: Floating mode charger voltage adjustment
Interface Setting
Parameter 2: you may choose
A
dd or Sub to adjust floating
charger voltage.
Parameter 3: the voltage range is from 0V to 6.4V, the default
value is 0V.
17: Constant charger voltage adjustment
Interface Setting
Parameter 2: you may choose Add or Sub to adjust constant
charger voltage.
Parameter 3: the voltage range is from 0V to 3.2V, the default
value is 0V.
18: Maximum charger current setting
Interface Setting
Parameter 3:
The maximum charging current could be adjusted.
Default value is 4A.
The available options are 1A, 2A, 4A and 6A.
19: Battery capacity and strings setting
Interface Setting
Parameter 2:
Set the battery capacity such as 7AH, 9AH, 10AH, 12AH, 17AH,
26AH, 40AH, 65AH, 100AH and so on.
The default value is 9AH.
Parameter 3:
Set battery string range from 1 to 6.
The default value is 1.