3-20
CDD3000-HF Operation Manual
3 Installation
3.6.2 Standard
terminal
assignment
Terminal assignment in factory setting.
Figure 3.9 Standard terminal assignment
Features
Preset solution, speed control with
+
10 V reference input (ISA00)
X2 Des. Function
20 OSD03 Not assigned
19 GND03 Not assigned
18 VCC03 Not assigned
17 OSD02 Not assigned
16 OSD02 Not assigned
15 OSD01 Loop control active
14 OSD00 Device ready
13 DGND Digital ground
12 ISD04 Not assigned
11 ISD03 Not assigned
10 ISD02 Not assigned
9 ISD01 Not assigned
8 ISD00 Start loop control
7 ENPO
Hardware enable of power
6 DGND Digital ground
5
U
V
Auxiliary voltage 24 V
4 ISA01- Not assigned
3 ISA01+ Not assigned
2 ISA00- Differential analog reference -
1 ISA00+ Differential analog reference +
Note the following points:
For terminal assignments for further preset solutions refer to
CDD3000 Application Manual.
ENPO
START
ACTIV
C_RDY
ISA0-
ISA0+
+10 V
ISA0-
ISA0+
or
CNC or
PLC