EasyManua.ls Logo

Lust CDD34.005-HF - Motor Temperature Monitoring

Default Icon
100 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CDD3000-HF Operation Manual
3-7
3 Installation
DE
EN
FR
IT
ES
FR
1
2
3
4
5
A
3.3.2 Motor
temperature
monitoring
Figure 3.3 Connection of the temperature sensor
For thermal monitoring of the motor winding, the temperature sensors
specified in Table 3.1 can be connected to terminals X3 / ϑ- and ϑ+.
Attention: Contrary to DIN VDE 0660-303 (short circuit dedection
<20) the CDD3000-HF will note a short circuit at < 50 .
For commissioning the correct type of temperature sensor used in the
connected motor must be set up. This measure is not necessary if a
matching motor data set is available.
Sensor
Tech. data
No PTC
used
Standard
PTC
Linear
voltage evaluation
TSS,
thermostatic
circuit-breaker
Usable type -
PTC based on
DIN44082
KTY84, yellow Klixon
Parameters
330-MOPTC =
OFF DIN KTY TSS
Measurement
voltage U
MAX
–12 V
Table 3.1 Motor temperature monitoring specification
X3
M
3~
1
V
2
U
W

Related product manuals