3-18
CDD3000-HF Operation Manual
3 Installation
3.6.1 Specification of
control
connections
No. Des. Specification Isolation
Analog
Inputs
1
2
3
4
ISA00+
ISA00-
• ISA00: U
IN
= ± 10 V DC, resolution 12-bit,
sampling time 1 ms (special function 125 µs)
ISA01+
ISA01-
• ISA01: U
IN
= + 10 V DC, resolution 10-bit,
sampling time 1 ms
• Tolerance: ± 1% of meas.
• 24 V digital input, PLC-compatible
Switching level Low/High: <4.8 V / > 8 V DC
Sampling time 1 ms
•R
IN
= 110 kΩ
Digital
Inputs
8
9
10
11
12
ISD00
ISD01
ISD02
ISD03
ISD04
• ISD00-ISD02: Frequency range < 500 Hz,
sampling time 1ms
• ISD03-ISD04: Frequency range < 500 kHz,
sampling time 1ms (special functions < 2
µs)
• PLC-compatible
Switching level Low/High: <5 V / > 18 V DC
•I
max
(at 24 V) = 10 mA
•R
IN
= 3 kΩ
✓
7 ENPO • Hardware enable of power stage = High level
• Specification as ISD00
✓
Digital
Outputs
14 OSD00 • Short-circuit-proof
• PLC-compatible, sampling time 1 ms
•I
max
= 50 mA, high-side driver
• Protection against inductive load
✓