CDD3000-HF Operation Manual
3-11
3 Installation
DE
EN
FR
IT
ES
FR
1
2
3
4
5
A
Pin assignment You can enter your custom assignment in the columns for connector B.
Technical data of LUST encoder cables
These cables are supplied ready made-up in various lengths.
Connec-
tor A
Function
Sine/cosine
SSI
function
HIPERFACE
®
function
Connec-
tor B
Wire
colour
CDD3000-
HF X7
Custom
1
A- A- REFCOS
2
A+ A+ +COS
3
+5 V / 150 mA +5 V / 150 mA
4
DATA+ Data+ RS485
5
DATA- Data- RS485
6
B- B- REFSIN
7
Us 7-12V /
100mA*
8
GND GND GND
9
R-
10
R+
11
B+ B+ +SIN
12 +5 V / (sensor) +5 V / (sensor)
13 GND (sensor) GND (sensor)
14 CLK+
15 CLK-
Outer and inner shield (if fitted) on both sides of housing
* To 250 mA with external +24 V (-5 %/+20 %) supply via terminal X2 permitted.
Table 3.5 Encoder cable pin assignment
KRY-KSxxx
1)
KGN-KSxxx
1)
KGS-KSxxx
1)
KGH-KSxxx
1)
drive controller type CDD3000-HF
Motors with encoder system
R1, R2, R8,
K1, K2, K8
G1 G2, G3, G5 G6, G7
Festoon-compatible yes
Table 3.6 Technical data of LUST encoder cables