CDD3000-HF Operation Manual
A-3
 
DE
EN
FR
IT
ES
FR
1
2
3
4
5
A
CDD34.008-HF to CDD34.032-HF 
1)
 Data referred to output voltage 400 V and switching frequency 8 kHz
.
Designation
Technical data
CDD34.008-HF
CDD34.010-HF
CDD34.014-HF
CDD34.017-HF
CDD34.024-HF
CDD34.032-HF
Output, motor end
1)
Device rated power 5.4 kVA 6.9 kVA 9.7 kVA 11.8 kVA 16.6 kVA 22.2 kVA
Voltage 3 x 0 ... 400/460 V
Continuous current (RMS) (I
N
)
7.8 A 10 A 14 A 17 A 24 A 32 A
Peak current 1.8 x I
N
 for 30 s
14 A 18 A 25 A 31 A 43 A 58 A
Rotating field frequency 0 ... 1600 Hz
Switching frequency of power stage 4, 8, 12, 16 kHz
Input, mains side
Mains voltage 3 x 400 V / 3 x 460 V -25 % +10 %
Current (with line choke)  8.2 A 10.5 A  14.7 A  17.9 A 25.3 A 33.7 A
Frequency 50/60 Hz ±10 %
Power loss at 4 / 8.16 kHz  [W] 150 / 177 187 / 222 225 / 283 270 / 340 330 / 415 415 / 525
Braking chopper power electronics
Peak braking power with int. 
braking resistor (only with version 
CDD34 ..., Wx.x, BR)
6.0 kW
at 90 
Ω
6.0 kW
at 90 
Ω
6.0 kW
at 90 
Ω
Minimum ohmic resistance of an 
externally  installed braking resistor
81 
Ω  47 Ω 22 Ω