AC Voltage ( True RMS )
Range 4 V/40 V/400 V/1000 V
Resolution 1 mV /10 mV /100m V/1 V
Accuracy ± (1%+2d )
* Spec. are tested under 50/60 Hz.
Input impedance 10 M ohm.
Over load ± 1000 DCV, 1000 ACV - other ranges.
protection
AC Current ( True RMS )
DC Current
Range 10 A/400 mA/40 mA/4000 uA/400 uA
Resolution 10 mA/0.1 mA/0.01 mA/1 uA/0.1 uA
Accuracy 400 mA/40 mA/4000 uA/400 uA :
± (0.5%+2d )
10 A :
± (1.5%+2d )
* ACA spec. are tested under 50/60 Hz.
Over load 10A range : 10A fuse.
protection uA, mA range : 500 mA fuse.
Diode ( Forward voltage, VF )
Range 4 V DC.
Resolution 0.001 V.
Accuracy ± (0.5%+2d )
Capacitance
Range 40 nF/400 nF/4 uF/40 uF
Resolution 10 pF/0.1 nF/1 nF/10 nF
Accuracy < 2 nF : ± (3%+20d )
Others : ± (3%+1d )