EasyManua.ls Logo

Lutron Electronics Sivoia QS - Ceiling Mount

Lutron Electronics Sivoia QS
24 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
BA
Top View
Within 8 in
(203 mm)
16-24 in
(406-610 mm)
16-24 in
(406-610 mm)
16 in
(406 mm)
16 in
(406 mm)
Within 8 in
(203 mm)
Window/Wall Side
Sivoia QS Drapery System Installation Guide
Page 3
2
Ceiling-Mount
2 .1 Fasten the ceiling-mount cam-locks to the ceiling:
A. Hold the drapery track up to the ceiling, and position it where it will be installed. Verify it is
parallel to the window or wall, and use a pencil to make a mark on the ceiling at each end.
B. Mount a cam-lock within 8 in (200 mm) of each end-mark made in Step 2.1A.
C. Mount the next cam-locks 16 in (406 mm) inward from those mounted in Step 2.1B.
D. Space the remaining cam-locks 16-24 in (406-610 mm) apart. For non-sheer drapery panels,
a 16 in (406 mm) spacing is recommended between brackets at stackback location(s).
IMPORTANT: Each cam-lock must be installed with a washer as shown. The cam-locks
must be mounted in a straight and level line. If the contour of the ceiling is not straight
and level, use shims (not included) between the cam-lock washers and the ceiling to
compensate for irregularities.
Top View
Window/Wall Side
Within Within
Cam-Lock Mounting
(not included; use a #8 screw
of appropriate length and thread
type for the supporting structure)
Ceiling
Washer
Mounting Screw
Cam-Lock
Top View
Window/Wall Side
Unlocked
Lock
Track
8 in
(203 mm)
8 in
(203 mm)
16-24 in
(406-610 mm)
16-24 in
(406-610 mm)
16 in
(406 mm)
16 in
(406 mm)
2.2 Mount the drapery track in the cam-locks:
A. Rotate all of the cam-lock lever arms to the unlocked position.
B. Position the track up against the cam-locks. Starting from the center of the
track and working toward the ends, rotate each cam-lock lever arm to the
locked position, until its tab is against the track.
IMPORTANT: The drapery track must be fully supported by at least two people
until all of the cam-locks are securely engaged.
C. Proceed to section 4: Electronic Drive Unit (EDU) Installation.
IMPORTANT: Each ceiling-mount cam-lock must be installed into a structural member using an appropriate fastener. Ensure the
structural member is of sufficient strength to support the combined weight of the drapery track, EDU, and fabric.
If no appropriate structural member is available at the mounting location, it is the responsibility of the installer to add blocking
as necessary to safely support the operating load of the system, including tugging that may occur during manual or attempted
manual operation.