Chapter 5: Advanced Synthesizer and Effects Editing
52
Venom User Guide
You can change the Waveform for LFO 2 by adjusting the LFO 2 Shape knob on the top panel Performance
Controls matrix (knob 3, row 5), or using MIDI CC 15. The Waveform for LFO 1 and LFO 3 can be changed
using MIDI CC 87 and MIDI CC 85 respectively. The following values select the corresponding waveform:
0 = Sine, 1 = Sine+, 2 = Triangle, 3 = Saw, 4 = Square, 5 = Sample and Hold, 6 = Linear Sample and Hold,
7 = Logarithmic Sample and Hold, 8 = Logarithmic Square, 9 = Exponential Square, 10 = Logarithmic Up Saw,
and 11 = Exponential Up Saw.
Tempo Sync Synchronizes the LFO cycle to note divisions of Tempo. When this parameter is on, the Rate pa-
rameter is measured in musical note divisions (such as 1/8-note or 1/16-note).
Rate Determines the frequency (0.01 Hz–30 Hz) of the LFO. You can change the Rate for LFO 1 by adjusting
the LFO 1 Rate knob on the top panel Performance Controls matrix (knob 1, row 5), or using MIDI CC 86; and
for LFO 2 by adjusting the LFO 2 Rate knob on the top panel Performance Controls matrix (knob 2, row 5),
or using MIDI CC 14. The Rate for LFO 3 can be changed using MIDI CC 84.
When changing the Rate using MIDI CC, values of 0–110 specify a fixed LFO rate. Values of 111 and higher
specify a tempo synchronized ratio as follows (expressed in rhythmic note values where the quarter note is the
beat): 111 = 1/32, 112 = 1/24 (or triplet sixteenth), 113 = 1/16, 114 = 1/12 (or triplet eighth), 115 = 1/8, 116 =
1/6 (or triplet quarter), 117 = 1/4, 118 = 1/3 (or triplet half), 119 = 1/2, 120 = 1/1, 121 = 2/1, 122 = 3/1, and
123 = 4/1.
Delay Determines the amount of time (0–20 sec.) the onset of the LFO is delayed after the voice is triggered.
LFO Delay is not available in LFO 3. The LFO Delay for LFO 1 and 2 can be edited using MIDI CC 90 and MIDI
CC 18 respectively.
Attack Sets an attack time (0–20 sec.) from 0 level to maximum level of the LFO. The attack time begins at the
onset of the LFO. Ramp is not available in LFO 3. The LFO Ramp for LFO 1 and 2 can be edited using MIDI CC
89 and MIDI CC 17 respectively.
Start Phase Sets the starting phase (0–359 Degrees) of the LFO wave, which begins at the onset of the LFO.
Start Phase is not available in LFO 3. The LFO Start Phase for LFO 1 and 2 can be edited using MIDI CC 88 and
MIDI CC 16 respectively.
A-MOD
The A-Mod section provides amplitude modulation controls for Tremolo and Auto Pan effects.The Tremolo
and Auto Pan effects are available on any Single Program and are independently available on each Multi Part
of a Multi Program.
Waveform Selects the shape (Sine, Triangle, Saw Up, Saw Down, or Square) of the LFO used for controlling the
Tremolo and Auto Pan effects.
Tempo Sync Synchronizes of the Rate of the LFO to the current tempo.
Rate Adjusts the rate (0.01 Hz–30 Hz) of the LFO used for controlling the Tremolo and Auto Pan effects.
Tremolo Adjusts the amount (0–100%) of the Tremolo effect.