49 AATime0 (0.1s) [0, 65535] Power supply time for autoclave (internal code for unit of measurement)
50 AATime1 [0, 65535] Power supply time for autoclave (internal code for unit of measurement)
51 AUTime0 (0.1s) [0, 65535] Time of use for autoclave (internal code for unit of measurement)
52 AUTime1 [0, 65535] Time of use for autoclave (internal code for unit of measurement)
53 DeltaBarTime [0, 15] Time variation of pressure
54 RelTime [0, 250] Deactivated PID time for switching off and on of external motors (For
version with contactors)
55 RemoteON Enable
[ON,OFF] If ON, the inverter is in STANDBY and wait external command to start
56 ExtMotor1Feedback
[0, 1023] Thermal state for external motor 1(For version with contactors)
57 ExtMotor2Feedback
[0, 1023] Thermal state for external motor 2 (For version with contactors)
58 MinHold [1, 29000] Continuous time of pump OFF in 24 hours
59 NoMinHtime [0, 1440] Display Continuous time of pump OFF
60 Leakages [0, 100] Counter for leakages
61 Garden Mode [0, 1] OFF/ON for garden mode
62 Imon Offset Set the offset for Imon (par.19)
63 PmaxNoflux_Time
Display time of air in pump
64 MinTresholdPar [0, 89.99] Activation parameter for second pump (in Xp version)
65 Tot ShortC done [0, 1000] Counter for short circuit ph-ph or ph-gnd. Initial value equal 40.
66 S/N1 [0, 32767] Serial Number
67 S/N2 [0, 32767] Serial Number.
68 Sector1 Pressure [1, 7.5] Available on in GardenMode = ON
69 Sector2 Pressure [1, 7.5] Available on in GardenMode = ON
70 Sector3 Pressure [1, 7.5] Available on in GardenMode = ON
71 Sector4 Pressure [1, 7.5] Available on in GardenMode = ON
72 System Pressure [1, 7.5] Desired Pressure for the System
73 NoGardenRestPres
[1, 7.5] Restart pressure
of the Hydrocontroller, it works only in GardenMode =
OFF
74 Rotation Sense [0, 1]
It changes the rotation sense of electropump via software (only with
three-phase electro pumps)
77 System Start [ON,OFF] Powers or Not the electropump
Save&Exit with Enter Key ENTER: save in permanent memory all the parameters