Macurco GD-xx Operation Manual
REV 2.0.0 [34-2900-0027-6 ] 24 | Page
4.5.13 4-20mA Output setting “420”
To select the 4-20mA Output Option, in normal mode, push the Next button to get to “Con” or the Configuration
menu. Then push the Enter button to enter the Con menu. The twelfth selection is the “420 or 4-20mA Output
Option. Push Next eleven times to get to “420” then Enter. If the 4-20mA is “On” push Next to turn it to “OFF”
(flashing) then push Enter to confirm the change (solid) and push Enter again to return to “420” in the Con menu.
Push Next until “End” is displayed then push Enter to get back to normal operation.