Compact Single Jet Heat Meter
microCLIMA
Installation and Operating Instructions
microCLIMA
4
8. Error Codes
When the instrument detects an
error, the standard display changes
to include the error symbol and error
number alternating with the regular standard
display, total heat quantity. There are seven
possible causes of error, and they can appear in
combination with each other, depending on the
situation.
The occurring error is shown on the LCD in the
format “Err xx”. The xx stands for the error no.,
shown in hexadecimal form.
For example, Err 08 -> scanning coil fault
Error Code
left digit right digit
error code
(hexadecimal)
check sum fault
E²PROM fault
reset
error code
(hexadecimal)
scanning coil
fault
ref-sensor fault
rf-sensor fault
ff-sensor fault
1x X
x1 X
2x X x2 X
3x X X
x3 X X
4x X x4 X
5x X X
x5 X X
6x X X x6 X X
7x X X X
x7 X X X
8x x8 X
9x X
x9 X X
Ax X xA X X
Bx X X
xB X X X
Cx X xC X X
Dx X X
xD X X X
Ex X X xE X X X
Fx X X X
xF X X X X
Error description
Error Description Effect Possible cause
ff-sensor
fault
The forward flow tempera-
ture sensor is defective.
No calculations are carried out.
The registers for flow and energy
are not being updated (no new
data is being stored).
Sensor cable severed; sensor
cable shorted out.
rf-sensor
fault
The return flow temperature
sensor is defective.
No calculations are carried out.
The registers for flow and energy
are not being updated (no new
data is being stored).
Sensor cable severed; sensor
cable shorted out.
ref-sensor
fault
Error during the reference
measurement.
No calculations are carried out.
The registers for flow and energy
are not being updated (no new
data is being stored).
A defect on the calculator
circuit board.
coil fault The scanning is not func-
tioning properly.
No calculations are carried out.
The registers for flow and energy
are not being updated (no new
data is being stored).
Coil shorted out; connecting
cable between calculator hous-
ing and flow sensor damaged.
reset The calculator electronics
have been reset.
The measurements since the last
storage of data in the E
2
PROM
are lost (max. one day)
EMC
E²PROM
fault
No communication with the
E
2
PROM.
After a reset, the instrument is
without function.
Defective component
check sum
fault
The configuration of the
instrument stored in the
E²PROM is not correct.
No calculations are carried out.
The registers for flow and energy
are not being updated.
Defective component
When an error occurs, with the exception of a reset error, the instrument must be exchanged and sent to the
manufacturer for examination.