EasyManua.ls Logo

Madimack ELITE V3 - Repairing Guidance and Personnel Requirements; Error Code and Failure Resolution

Madimack ELITE V3
58 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
49
1. Repairing Guidance
Requirements for Service Personnel
a. Any person who is involved with working on or breaking into a refrigerant circuit should hold a
current valid certificate from an industry-accredited assessment authority, which authorizes their
competence to handle refrigerants safely in accordance with an industry recognized assessment
specification.
b. Do not attempt to work on the equipment by yourself. Improper operation may cause danger.
c. Strictly comply with the manufacturer's requirements when charging R32 gas and equipment
maintenance. This chapter focuses on special maintenance requirements for swimming pool
heat pump with R32 gas. Please refer to the technical service manual for detailed maintenance
operation.
d. Vacuum system completely before welding. Welding should only be carried out by professional
person in a service center.
2. Problems without an error code
Failure
Reason
Solution
Heat pump doesn’t run
No power
Wait until the power recovers
Power switch is off
Switch on the power
Fuse is broken
Check and change the fuse
The breaker is off
Check and turn on the breaker
Fan running but with
insufficient heating
Evaporator blocked
Remove the obstacles
Air outlet blocked
Remove the obstacles
3-minute start delay
Wait patiently
Display normal, but no
heating
Set temperature too low
Set proper heating temp.
3-minute start delay
Wait patiently
***If above solutions don’t work, please contact your installer with detailed information and your model
number. Please don’t try to repair it yourself. ***
Note
If the following conditions happen, please stop the machine immediately, and cut off the power supply
immediately, then contact your dealer:
1. Inaccurate switch action.
2. The fuse is frequently broken or leakage circuit breaker jumped.
WARNING!
If repairs or removal is required,
contact authorized service center.