5-7
㽲 Run lamp
Lights when an ON command is issued but no frequency signal is sent out it blinks when operation is started.
㽳 PRG lamp
Lights when the inverter is in parameter setting mode. Blinks when the inverter is placed in AUH Gr. U mode.
㽴 MON lamp
Lights when the inverter is in monitor mode. Blinks when the inverter is placed in trip record display mode.
㽵 Percent (%) lamp
Lights when a numeric value is displayed in %.
㽶 Hertz (Hz) lamp
Lights when a numeric value is displayed in Hz.
㽷 Up key
㽸 Up/Down key lamp
Pressing up or down key when this lamp is lighted allows the setting of operation frequency.
㽹 Down key
㽺 RUN key lamp
Lights when the RUN key is enabled.
㽻 RUN key
Pressing this key while the RUN key lamp is lit starts operation.
㽼 STOP key
Every pressing of this key while the RUN key lamp is lit will cause a slowdown to a stop.
㽽 Built-in potentiometer
㽾 Enter key
㽿 MODE key
Displays operation frequency, parameters, and error causes.
㾀 Built-in potentiometer lamp
Operation frequency can be changed when the built-in potentiometer lamp is lit.
㾁 Charge lamp
Indicates that high voltage is still present within the inverter. Do not open the terminal board cover while this is lit.
㾂 Front panel
The panel of the inverter or terminal board
To avoid touching the terminal board by mistake, be sure to does the front panel before starting operation.
㾃 Unlock position mark
The front panel is unlocked when the dot on the locking screw is on this (upper) side.
㾄 Panel locking screw
The inverter came with this screw in the locked position. So from this position, turn the screw 90° counter clockwise to unlock the
front panel, or turn it 90° clockwise to lock the front panel.
The screw does not turn 360°. To avoid damage to the screw, do not use excessive force when turning it.
㾅 Lock position mark
The front panel is unlocked when the dot on the locking screw is on this (lower) side.
193