INSTALLATION DRAWINGS
t
2 114"
36' HEIGHT
OF CABINET
300_ECABiNET
NING._..,_
RECOMMENDED GAS LINE
LOCATION SELF-CLEAN
MODELS.
3 I14"
ED GAS LINE
LOCATION NON-SELF
CLEANING MODELS,
FOR 120 VOLT
GROUNDED ELECTRJCAL
OUTLET IN tHIS AREA.
OUTLET MUST BE FLUSH.
AREA IS 13"W × g'H,
LOCATED 9 3/_" ABOVE
FLOOR, AND 1 112' FRO_iI
RIGHT WALL.
24* CABINET
DEPTH
25" NORMAL
CABINET
DEPTH
*- ALLOWED 18" FOR
NON-CONVECT MO,DELS.
'231/4"
DEPTH
NOTE:
ON CABINET TOPS WITH
FORMED FRONT EDGE, SHAVE
RAISED SECTION TO CLEAR TOP.
PROVIDEFOR120VOLT
GROUNDEDELECTRICAL
OUTLETINTHISAREA.
OUTLETMUSTBEFLUSH.
36" HEIGHT
OF CABINET
/ I / RECOMMENDED GAS
CAUTION: _ CEAB INGET_/'I_
SOME WHITE EUROPEAN STYLE CABINETS ARE EQUIPPED WITH DELICATE
WHITE VINYL DRAWER AND DOOR FRONTS. THE VINYL MAY NOT BE
DESIGNED TO WITHSTAND THE HEAT PRODUCED BY THE NORMAL SAFE
OPERATION OF A SELF-CLEAN RANGE. DISCOLORATION OR DELAMINATtON
MAY OCCUR. TO AVOID POSSIBLE DAMAGE, WE RECOMMEND INCREASING
THE 30" CABINET OPENING TO 31 1/4" MINIMUM AND USING HEAT SHIELD
KIT-CABKIT V. THE COUNTERTOP CUT-OUT MUST REMAIN 30".
FLATAREA ,,_
_._ 25" MINIMUM
CABINET
TOPDEPTH
24" CABINET
* Whenreplacinganexistingunit,a maximumof23 1/2"isacceptable.Ifthecutdepthexceeds23 1/2",usefillerkit(K70Fill).
-2-