Note:
If you want to carry out any other changes, start the whole process over again.
If you hear a long beep, you are out of programming menu area. Start again by the step
1.
Failure notice:
If the remote happened to be out of the range when programming changes, it will display
„FAIL“ notice and the programming will be cancelled.
Programming menu No. 1
When the door is open and ignition is on keep buttons I and II pressed simultaneously for
2 sec.
Options
No. Function
Button I Button II Button III Button IV
1-04
Emergency code RPS
Off On - -
1-06
Flashing when the doors
are open
Off On - -
1-08
Flashing when the trunk
is open
Off On - -
1-10
PIN code
Off On - -
1-11
Start kill/IG kill
IG kill Start kill - -
1-12
Dome light delay
Off 5 sec 15 sec 50 sec
1-14
CAN mode
Read only Read and Write
Read, Write and
close windows
-
Functions description:
1-04 When on, you can enter a 4-digit emergency code to cancel the alarm and open the
car.
1-06 When on, alarm will warn of the door opened by flashing the lights.
1-08 When on, alarm will warn that the hood is open by flashing the lights.
1-10 It allows you to enter the valet mode in two ways:
- simple access – by turning ignition on/off 3 times in row
- secure access – by turning ignition on/off 3 times in row and entering a 2-digit PIN code by
the button on the back side of RPS.
1-11 In case of using the IG kill function, the blocking output is – active (on -250mA) when
armed, - inactive during a remote starting and disarmed; in case of using the PANIC function
when disarmed, the output will be activated after 30 sec. In case of using the Start kill function,
blocking output is – active when armed and remotely started, - inactive when disarmed; in
case of using the PANIC function when disarmed, the output will be activated immediately.
1-12 It is possible to set up a delayed reaction to opened door contacts when turning on the
alarm. The function is supposed to be used with indirect closed doors scanning (from the roof
light, etc.)
1-14 This function is available with CAN BUS Magicar module. In case of using the Read only
function, Magicar only read CAN information (open door, trunk, hood, lock/unlock with OEM
remote, etc.)
In case of using the Read and Write function, Magicar can also control lock/unlock,
lights and klaxon except closing windows.
In case of using the Read, Write and close windows, Magicar can also close windows
when armed.*
* See possible function Module CAN BUS Magicar in Table of functions depending on car
type.
Programming menu No.2
When the doors are opened and ignition is on, keep the buttons I and IV pressed for 2
sec.