IMPULSE®•G+ & VG+ Series 3 to Series 4 Transition Guide August 2011
Page 33 of 54
Magnetek, Inc.
Product Transition Guide
IMPULSE
®
•G+ & VG+ Series 4
Zero-Speed Oper
B3-05
(VG+ only)
0
B3-05
(VG+ only)
0
0: RUN at Freq
Ref
0: RUN at Freq
Ref
1: Stop 1: STOP
2: RUN at Min.
Freq (E1-09)
2: RUN at Min.
Freq (E1-09)
3: RUN at Zero
RPM
3: RUN at Zero
RPM
# of Input Scans B3-06 1 B3-06 1
0: 2ms–2 scans 0: 1 scan (1 ms)
1: 5ms–2 scans 1: 2 scans (2 ms)
LOC/REM Run
Sel
B3-07 0 B3-07 0
0: Cycle Extrn Run 0: Cycle Extrn Run
1: Accep Extrn
Run
1: Accep Extrn Run
Run Command at
Program
B3-08 0 B3-08 0
0: Disabled 0: Disabled
1: Enabled
1: Enabled (B3-
02=0 is Disabled)
Allow Run at
Power UP
B3-10 0 B3-10 0
0: Disabled 0: Cycle Ext Run
1: Enabled 1: Accept Ext Run
MOP Ref Memory B4-01 0 -- --
0: Disabled --
1: Enabled --
Trim Control LVL B4-02 10% -- -- --
Accel Time 1 B5-01 5.0 sec B5-01 5.0 sec --
Decel Time 1 B5-02 3.0 sec B5-02 3.0 sec --
Accel Time 2 B5-03 2.0 sec B5-03 10.0 sec --
Decel Time 2 B5-04 2.0 sec B5-04 10.0 sec --
Accel Time N Chg B5-05 2.0 sec B5-05 2.0 sec --
Dec Time N Chg B5-06 2.0 sec B5-06 2.0 sec --
Fast Stop Time B5-08 0.5 sec B5-08 0.5 sec --
Acc/Dec Units B5-09 1 B5-09 1
0: 0.01sec for
0.00–2.55 sec
0: 0.01sec for
0.00–2.55 sec
1: 0.1sec for 0.0–
25.5 sec
1: 0.1sec for 0.0–
25.5 sec
Acc/Dec SW Freq B5-10 120.0 Hz B5-10 0.0 Hz --
SW Freq
Compare
B5-11 1 B5-11 1
0: Lower SW Freq 0: Lower SW Freq
1: Upper SW Freq 1: Upper SW Freq
Accel Time 3 B5-12 3.0 sec B5-12 3.0 sec --
Decel Time 3 B5-13 3.0 sec B5-13 3.0 sec --
Accel Time 4 B5-14 3.0 sec B5-14 3.0 sec --
Decel Time 4 B5-15 3.0 sec B5-15 3.0 sec --
Parameter
Name
Series 3 Series 4 Comments
No. Default No. Default Series 3 Series 4