  • N
    Nicholas SwansonNov 2, 2025
    What to do if Magnetrol TD1-2D00-0 indicates a fault (red LED blinks)?
    • S
      Shawna GayNov 2, 2025
      If the Magnetrol Switch indicates a fault, and the red LED is blinking, the solution depends on the cause: * **Liquid Level – Sensor Wet:** Verify HEATER (TD1) / HTR (TD2) is set to “–”. Change HEATER/HTR to “+”. If the light goes off, contact the factory to discuss the application. If the light stays on, check the resistance to determine if a problem exists with the probe or electronics. * **Liquid Level – Sensor Dry:** Verify HEATER (TD1) / HTR (TD2) is set to “–”. Turn off FAULT (TD1) / FLT (TD2). If the light goes off, operate in this mode. If the light stays on, check the resistance to determine if a problem exists with the probe or electronics. * **Liquid Flow – Sensor Dry or Air Flow – None:** Turn off FAULT (TD1) / FLT (TD2). If the light goes off, run HEATER/HTR at “+” and ...

Summary

Safety and General Information

Quick Start and Installation Basics

Quick Start Guide

Initial setup and calibration adjustment guide for the unit.

Unpacking and ESD Handling

Procedures for unpacking, inspecting, and handling components safely.

Mounting the Thermatel Switch

Mounting Installation Steps

Detailed steps for applying thread sealant and inserting the sensor.

Mounting Orientation and Precautions

Guidelines on sensor orientation, access, and environmental considerations.

Wiring and Connections

Power and Relay Wiring

Details on connecting power supply, control wires, and performing relay connections.

Relay Connections and Operation

TD2 Remote Electronics and mA Output

Switch Setup and Configuration

General Switch Settings

Details on setting the four-position and two-position switches for application.

LED Indicators and Time Delay (TD2)

Calibration Procedures

Calibration Setup and Fail-Safe Modes

Details on setting switches, fail-safe modes, and their effect on LEDs.

LEVEL Application Calibration

Step-by-step guide for calibrating level applications.

Level Calibration Applications

High Level Application Calibration

Detailed calibration steps for high level detection.

Low Level Application Calibration

Detailed calibration steps for low level detection.

Interface Application Calibration

Calibration procedure for interface detection using dual fluids.

Flow Calibration Procedures

Low;No Flow Calibration

Step-by-step guide for calibrating low flow/no flow detection.

Flow Rate Calibration and Troubleshooting

High Flow Calibration

Step-by-step guide for calibrating high flow detection.

Advanced Calibration and Fault Detection

TD2 Advanced Calibration

Procedure for measuring and recording voltage for calibration reference.

Fault Detection Overview

Explains the self-diagnostic features and fault mode indication.

Troubleshooting and Maintenance

Troubleshooting Guide

Table of symptoms, applications, and actions for troubleshooting.

Probe Replacement Procedures

Probe Specifications and Options

Performance Specifications

Probe Configurations and Materials

Magnetrol TD1-2D00-0 Series Specifications

General IconGeneral
SeriesTD1-2D00-0
CategorySwitch
Material316 Stainless Steel
Temperature Range-40 to 85 °C
Process ConnectionNPT
Enclosure RatingNEMA 4X