EasyManua.ls Logo

Magnetrol TD1-2D00-0 Series User Manual

Magnetrol TD1-2D00-0 Series
32 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Thermal Dispersion
Flow/Level/Interface
Switch
Model TD2
with low flow body
Model TD2
with spherical probe
Model TD1
with twin-tip probe
Thermatel
®
Model TD1/TD2
Installation and Operating Manual
Question and Answer IconNeed help?

Do you have a question about the Magnetrol TD1-2D00-0 Series and is the answer not in the manual?

Magnetrol TD1-2D00-0 Series Specifications

General IconGeneral
SeriesTD1-2D00-0
CategorySwitch
Material316 Stainless Steel
Temperature Range-40 to 85 °C
Process ConnectionNPT
Enclosure RatingNEMA 4X

Summary

Safety and General Information

Quick Start and Installation Basics

Quick Start Guide

Initial setup and calibration adjustment guide for the unit.

Unpacking and ESD Handling

Procedures for unpacking, inspecting, and handling components safely.

Mounting the Thermatel Switch

Mounting Installation Steps

Detailed steps for applying thread sealant and inserting the sensor.

Mounting Orientation and Precautions

Guidelines on sensor orientation, access, and environmental considerations.

Wiring and Connections

Power and Relay Wiring

Details on connecting power supply, control wires, and performing relay connections.

Relay Connections and Operation

TD2 Remote Electronics and mA Output

Switch Setup and Configuration

General Switch Settings

Details on setting the four-position and two-position switches for application.

LED Indicators and Time Delay (TD2)

Calibration Procedures

Calibration Setup and Fail-Safe Modes

Details on setting switches, fail-safe modes, and their effect on LEDs.

LEVEL Application Calibration

Step-by-step guide for calibrating level applications.

Level Calibration Applications

High Level Application Calibration

Detailed calibration steps for high level detection.

Low Level Application Calibration

Detailed calibration steps for low level detection.

Interface Application Calibration

Calibration procedure for interface detection using dual fluids.

Flow Calibration Procedures

Low/No Flow Calibration

Step-by-step guide for calibrating low flow/no flow detection.

Flow Rate Calibration and Troubleshooting

High Flow Calibration

Step-by-step guide for calibrating high flow detection.

Advanced Calibration and Fault Detection

TD2 Advanced Calibration

Procedure for measuring and recording voltage for calibration reference.

Fault Detection Overview

Explains the self-diagnostic features and fault mode indication.

Troubleshooting and Maintenance

Troubleshooting Guide

Table of symptoms, applications, and actions for troubleshooting.

Probe Replacement Procedures

Probe Specifications and Options

Performance Specifications

Probe Configurations and Materials

Related product manuals