95
Fill to correct level
Change to correct oil
Replace faulty part
Contact dealer for repair
Low oil level
Wrong oil
Faulty light or switch
Clogged oil filter
Oil warning light comes
on with the engine
running
Contact dealer for repair
Contact dealer for repair
Contact dealer for repair
Contact dealer for repair
Contact dealer for repair
Fill the tank and check fuel
quality
Clean the element
The injectors are clogged,
carbon coated and sticking
Low compression
Leaking valve seat
Incorrect valve gap
Faulty timing
Fuel shortage
Clogged air cleaner
Reduced performance of
the engine
Reduce to correct quantity
Contact dealer for repair
Oil level too high
Shortage of or faulty fuel
White smoking from the
exhaust
Engine
Contact dealer for repair
Contact dealer for repair
Top up or replace
Replace or adjust
Wiring fault
Faulty alternator
Low water level or faulty
battery
Broken or loose fan belt
Alternator light comes on
with the engine running
REMEDYCAUSESYMPTOM

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mahindra 10 Cab Series 4510C and is the answer not in the manual?

Mahindra 10 Cab Series 4510C Specifications

General IconGeneral
BrandMahindra
Model10 Cab Series 4510C
CategoryTractor
LanguageEnglish

Related product manuals